How many wires with a diameter of 1.2 mm are needed to make a wire with a cross section of 6 mm.sq.?
How many wires are needed with a diameter of 1.2 to get a wire with a cross section of 6 mm.sq.? Do I need to solder them and where?
How many wires are needed with a diameter of 1.2 to get a wire with a cross section of 6 mm.sq.? Do I need to solder them and where?
I laid 2 cables from the staircase. Can I draw a line through a power outlet (PE) to a switch? Fundamentally electrical outlet and switch. What are your recommendations?
I want to extend the outlet for the washing machine to the bathroom. The machine's power is 1700 watts, there is a copper wire VVG 3 * 1.5. Can I use such a wire?
My task is to provide power to the construction site. I want to ask advice on how to correctly calculate the power supply of a construction site?
Indesit WIUN 81 washing machine. I set the washing mode, everything on the panel lights up as expected, the door locks, but does not pump water. Spin mode does not work.
They put a voltage regulator in the house. If we try to turn on more than two devices, the machine knocks out on the counter, which was not the case without the stabilizer earlier.
Chandelier for three horns. In one of the three, the 7W lamp is off. Replacing it with the same 10W, everything is on normally. The cartridge is working, the base and the turns on the lamps are identical.
There is an electromagnet in the toaster, wound on a coil of dielectric wire with a thickness of hair. The magnet itself burned out when the ejection mechanism jammed. What to do?
The water heater and heating boiler go to the set temperature mode for a very long time. Can I solve the problem by installing a three-phase stabilizer at the entrance to the house?
We have installed LED lamps mr16-4w-840-gu5.3 in our kitchen. We worked for 4 years and began to flicker, set new ones - the problem remained. What's the matter?
Due to the lack of grounding of the PC, the power supply gives out 110v to the case, hdd dies due to the static and contacts the audio jack on the case. How can this problem be solved?
2 electric heating circuits of 8 kW each. What time relay and start relay are needed for alternating switching circuits daily. The heating period is 6 months.
When washing is complete, the drain pump does not turn off. Continues to work until the plug is removed from the outlet. That is, the dishwasher does not complete the program. What to do?
What batteries should I buy so that the device works as long as possible on a single charge instead of a 9V crown battery? There is a variant of Li-polymer and Li-Ion.
Is it possible to use a computer UPS and powerful AGM batteries (instead of a standard low-volume one) to connect a heating pump through a converter (12v - 220v)?
I would like to make zone lighting - two groups of lamps and a central chandelier, but there is only one phase on the switch, the wallpaper is pasted. What to do?
I turn on the desk lamp in one extension cord with the computer, the speakers begin to buzz. If you turn on something else, then the speakers do not hum, buzz only on the lamp.
LED lamps have their own power supplies (Driver), the tape has its own unit. When you turn on the two keys, the diode lamps blink. How can this be fixed?
We recommend reading:
How to conduct electrical wiring in an apartment - all stages of electrical installation