Why connect the hood in the bathroom?
In the bathroom there are wires for the exhaust fan, when I installed it, I found out that there was no voltage on them. What could be the problem and where to look for the cause?
In the bathroom there are wires for the exhaust fan, when I installed it, I found out that there was no voltage on them. What could be the problem and where to look for the cause?
Is it safe to connect the PVA wires to the hard cable using PPE clamps in fixed wiring? The load will be up to 2 kW.
In an unheated room, increased humidity, moisture pulls from below, is it possible to lay a self-regulating cable for a plastic baseboard to warm the joint of the wall with the tiled floor?
You need to connect the TV on the boat. The TV is powered by 100 Volts, the power is 142 watts, while the standard inverter is turned off. What to do?
I have a two-gang switch for the kitchen and toilet. When I turn on the toilet, then turn on the kitchen, then turn off the toilet - the light in the kitchen goes out - why?
When you connect any device to any outlet, they emit extraneous noise similar to a loud microphone. We live in a private house, there is grounding. The wiring is new. Devices are serviceable.
The wire xuan hua xh03-f 250 v stretched out and shorted, a burning smell appeared, but quickly turned off. Can I use this wire further?
At the dacha, the voltage in the network reaches 160 volts, which is why I want to put a stabilizer on 20,000 VA. Will it work and solve the low voltage problem?
Received TU for connecting a garage of 7 kW. What introductory machine, metering device, protection device to install when assembling the metering board? TU does not say.
How to find out how the motor windings are connected (Star or delta), if only three wires are output. There is no nameplate on the engine. What voltage is also unknown.
The voltage of the transformer 36 V must be laid on the street, in the metal profile of the PUGB wire connected by VAGO. Is it necessary to use a corrugation and to close the connection itself with a coupling sleeve?
An electrician at the dacha bought controllers for 2007 production, without any documents. Is it possible to install them without verification?
Can I connect a contactor with a 380V coil from a conventional switch? That is, one contact (A1) is connected directly to the phase, and the second (A2) through the key switch to any other phase.
There is a passage switch in the corridor, but the light turns on only if you turn on two switches at once, control from several places does not work, where could there be a problem?
In the new apartment, they are now making electrical wiring from the builder, while using a ШВВП and ПУГВ cable. Can they be used for fixed wiring or is it better to replace it?
A 0.4 kV line was drawn to the facility. AVVG 4 * 25. The documents indicate that the permissible power is 20 kW. It is planned to add 3 more units of 2.7 kW. Do I need to change the cable?
It is necessary to remove the sconce in the children's room, but what to do with the remaining wires that protrude from the wall? Want everything to be neat and safe?
What brand of wire is needed for a submersible pump? For underwater applications, the HVV cable and runway wire are suitable, here you can familiarize yourself with its characteristics.
Installed a touch switch, but he does not want to work with LED spotlights with power supplies. When connected directly to 220V, everything works. What is the reason?
Tell us how the circuit breakers differ, in the same series, say the ABB brand, but with different amperes? ABB circuit breaker at 25A costs an average of 550r, and at 40A - 850r.
He spent electricity on the balcony for lighting and underfloor heating. This line is protected by an automatic machine and an RCD. Do I need to put another difavtomat on the balcony?
How can I realize opening and closing a door by timer? What controllers for automatic doors are there, how to do it right?
The house was for two owners, respectively, there were two counters. Later, the second half of the house was bought by one family. Hence the question, is it possible to disable one counter and leave 1 total?
In an old house built in 1914, I want to partially replace the wiring, tell me which machines to choose for the apartment electrical panel and the wire for wiring in the panel.