How to lay the cable through the doorway?
Good afternoon! The question is, I want to attach a separate wire from the shield to connect the boiler. Is it possible to gut the gate to the left of the flap parallel to the floor in the side of the doorway, insert it into the doorway, put it along the door frame (repeating the bending of the door frame) to the opposite side and again gut a piece of concrete wall towards the tube from the intercom and enter the void between hl sheets (partition between the hallway and the bathroom). Then, from there, raise the wire into the suspended ceiling and reach the toilet already on the ceiling from the bathroom?
Is it possible to lay the cable along the box and how best to lay it in the voids hl in the corrugation or not in the concrete wall ?! The cable will be 3 * 2.5 NYM. Attaching photo!
Hello! In the voids between the GCR, it is better to further protect the cable by laying it in the corrugation. A cable without corrugation can be laid in a concrete wall. According to the rules, it is recommended that the cable be laid at a distance of at least 10 cm from the doorways.