An approximate calculation of the operating time of the gas boiler from the battery

How to calculate the operating time of a gas boiler with an electric power of 130 W from a battery of 60 a / h 12V through a 220/12 inverter?

Loading...

One comment

  • Admin

    Hello! You need to convert the battery capacity to watt hours. For this, 60 A / h * 12 V = 720 W / h.
    Apparently this is a car battery. Please note that it is not recommended to deeply discharge it. Suppose we plant it up to 40% of the nominal capacity, then we have 432 watts of hours that can be safely used. Now we will take into account the efficiency of your inverter, even 80%. So we have left:
    432 * 0.8 = 345W / h
    Total 345W / h / 130W = 2.6 hours your boiler can work without harm to the battery. Further work, of course, will continue for the same amount and even longer, but so you risk killing the battery.

    To answer

Add a comment